Auto Shut-Off Of CO2 Solenoid Valve .

Auto Shut-Off Of CO2 Solenoid Valve

Monitors Up To 13 Zones: Rooms .

Monitors Up To 13 Zones/ Rooms

Complete Airflow Control .

Auto Control Of Exhaust Fan To Remove CO2

icon-auto-compliant

Compatible with the free TrolMaster App

TrolMaster makes it easy to control your grow environment — from small tents to large farms. Manage climate, irrigation, Lighting, and CO₂ with our modulair smart systems. Find the right setup for your needs.

AL1 /AL2 Line

The MBS-K30 CO2 sensor, designed for the Carbon-X CO2 Alarm System, monitors CO2 up to 30,000 ppm using NDIR technology. Mounted 12-18 inches from the floor, it displays current ppm on its LCD or a CDA-1 controller. The Carbon-X system supports one or two MBS-K30 sensors per zone across up to 13 zones. If CO2 exceeds a user-defined threshold, the CDA-1 controller initiates safety measures: audible/visible alarms (AS-1 to AS-5), CO2 supply shut-off (DSE-1), ventilation fan activation (DSC-1), and interface with building alarms (DSD-1), ensuring CO2 levels remain below 5000ppm to comply with regulations.

AL1 /AL2 Line

Device Line

The Carbon-X CO2 Alarm System includes AS-1 through AS-5 audible-visual alarm modules, which monitor and alert to unsafe CO2 levels. These stations, mountable inside or outside, provide audible and visible alarms when CO2 exceeds set limits. AS-2, AS-3, and AS-4 models have LCD displays and color-coded LEDs (AS-2: green/yellow/blinking red; AS-3: amber; AS-4: blue), while AS-1 and AS-5 feature a red strobe light. They connect to AL-1 or AL-2 CO2 sensor channels (or both) via an SPH-1 powered splitter hub and RJ12 cables, requiring addressing after connection. Alarm siren sound pressure levels are 85dB for AS-1/AS-5 and 100dB for AS-2/AS-3/AS-4.

Audible and Visible Alarm

Device Line

The Carbon-X CO2 Alarm System uses several modules for CO2 monitoring and safety. The DSE-1 CO2 Emergency Stop Station automatically cuts off CO2 supply if faults, high CO2, or communication loss are detected. The DSC-1 CO2 Device Station activates ventilation or supplemental CO2 devices for high CO2 or faults. The DSD-1 Dry Contact Station interfaces with building alarms or fire panels via dry contacts. The OM-8 Dry Contact Board controls various devices with multiple dry contact relays. The DCC-2 Dual System Control Adapter allows single modules (like DSC-1 or DSD-1) to work with both Hydro-X and Carbon-X controllers, with an interlock function for combined or independent operation.

Emergency Control

Build it your way
Discover modules that work perfectly together

What’s on your mind?

Find helpful resources and detailed information to guide you through every step.

Find a retailer near you